APEX CNO

APEX Daily Pulse — 2026-11-12

Matching Samples Do Not Identify Frequency

[✅ Verified] Pillar: Sensing and collection

[❓ Unverified] Estimated duration: 3–5 minutes

Reactivation target: Expose a frequency alias, then change the acquisition rate to distinguish two candidate sources.

Prerequisites

- Python 3.12+ with its standard math module.

- A Bash-compatible terminal on owned equipment.

- No privileges, network access, SDR hardware, or RF transmission.

Actions

  1. 1. Before running the fixture, predict whether 125 Hz and 875 Hz can produce the same real-valued samples at 1,000 samples per second.
  1. 2. Run the complete comparison. Both signals have unit amplitude, zero phase, and 64 samples:
python3 - <<'PY'
import math

def capture(frequency_hz: float, rate_hz: float) -> list[float]:
 """Generate 64 ideal real-valued cosine samples."""
 return [
 math.cos(math.tau * frequency_hz * n / rate_hz)
 for n in range(64)
 ]

def maximum_error(first: list[float], second: list[float]) -> float:
 """Return the largest corresponding sample difference."""
 return max(
 abs(a - b)
 for a, b in zip(first, second, strict=True)
 )

tolerance = 1e-10

error_1000 = maximum_error(
 capture(125.0, 1000.0),
 capture(875.0, 1000.0),
)

error_1200 = maximum_error(
 capture(125.0, 1200.0),
 capture(875.0, 1200.0),
)

indistinguishable_1000 = error_1000 < tolerance
distinguishable_1200 = error_1200 > 1.0

passed = (
 indistinguishable_1000
 and distinguishable_1200
)

print(f"samples_per_capture=64")
print(f"error_at_1000={error_1000:.3e}")
print(f"error_at_1200={error_1200:.3e}")
print(f"indistinguishable_at_1000={indistinguishable_1000}")
print(f"distinguishable_at_1200={distinguishable_1200}")
print(f"drill_passed={passed}")

raise SystemExit(0 if passed else 1)
PY
  1. 3. Compare the two error values. At 1,000 samples per second, the maximum difference must be below 1e-10. At 1,200 samples per second, it must exceed 1.0.
  1. 4. State the permitted conclusion: the second rate distinguishes these two candidates. It does not establish a unique source frequency among all possible frequencies.

Observable signal

[❓ Unverified] Expected flags; the fixture was not executed in this run:

samples_per_capture=64
indistinguishable_at_1000=True
distinguishable_at_1200=True
drill_passed=True

[✅ Verified] Mechanism: at integer sample index n, the 875 Hz signal at a 1,000 Hz sample rate is cos(2πn − 2π·125n/1000). This equals the sampled 125 Hz cosine. The sample sequences therefore match, apart from floating-point error. A longer capture at the same rate cannot separate this ideal pair.

Success condition

Both candidate signals match at the first rate. They differ at the second rate. The operator rejects a unique frequency claim based only on the first capture.

Failure signature

[✅ Verified] Reporting “source confirmed at 125 Hz” from the first capture alone is unsupported: the 875 Hz fixture produces the same observations under the declared conditions.

Python unavailable: POSIX awk alternative

Use awk and its built-in cosine function:

awk '
BEGIN {
 pi = atan2(0, -1)
 rate[1] = 1000
 rate[2] = 1200

 for (k = 1; k <= 2; k++) {
 peak[k] = 0
 for (n = 0; n < 64; n++) {
 a = cos(2 * pi * 125 * n / rate[k])
 b = cos(2 * pi * 875 * n / rate[k])
 difference = a - b
 if (difference < 0) difference = -difference
 if (difference > peak[k]) peak[k] = difference
 }
 printf "rate=%d maximum_error=%.3e\n", rate[k], peak[k]
 }

 passed = peak[1] < 1e-10 && peak[2] > 1
 print "drill_passed=" (passed ? "true" : "false")
 exit(passed ? 0 : 1)
}'

Boundary check

[✅ Verified] Hidden assumption: this fixture models real-valued sampling without an analog input filter. Complex I/Q sampling has different signed-frequency behavior. A correctly selected analog filter can reject the higher-frequency candidate before sampling; a digital filter applied after aliasing cannot recover the lost distinction.

[❌ Speculative] In a hardware drill, a second acquisition rate adds operator work and can change gain, bandwidth, or timing. Record those settings. Prefer an input filter when the permitted source band is known; use rate changes as a diagnostic when it is not.

Adaptation question

Which APEX frequency claims depend on a single sample rate without a verified input-band limit?